Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity

Samo za registrovane korisnike
2018
Autori
Tekić, Žikica
Nenadović, Aleksandra
Đorđević, Saša M.
Lukić, Snježan
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
This paper deals with the results of experimental determination of load-bearing capacity of structural timber connections realized by nail metal connector plates, in the function of nail to steel plate connection rigidity. In the first group of test samples, the nails are embedded in pre-drilled holes in the steel plate. In the second group, the nails are embedded in pre-drilled holes and then the head of nail is welded to steel plate by its circumference. The main originality of the study is reflected in the achievement of rigidity of the connection of nails and the sleet plate, that is, in provision of rotation resistance, which leads to the plastic hinge formation at the surface of the steel plate, and thus to the increase of connection ductility. The study showed to what extent the degree of nail-to-plate connection rigidity affects the load-bearing capacity of structural timber member connections. Experimental testing was conducted in accordance with the provisions of Eurocode 5.
Ključne reči:
Failure mode / Load-bearing capacity / Metal connector plate / Nail / Nail-to-plate connection rigidity
Izvor:
Wood Research, 2018, 63, 1, 85-95
Izdavač:
  • Statny Drevarsky Vyskumny Ustav

ISSN: 1336-4561

WoS: 000428122800008

Scopus: 2-s2.0-85042927269
[ Google Scholar ]
URI
http://raf.arh.bg.ac.rs/handle/123456789/309
Kolekcije
  • Publikacije istraživača / Researchers' publications
Institucija
Arhitektonski fakultet
TY  - JOUR
AU  - Tekić, Žikica
AU  - Nenadović, Aleksandra
AU  - Đorđević, Saša M.
AU  - Lukić, Snježan
PY  - 2018
UR  - http://raf.arh.bg.ac.rs/handle/123456789/309
AB  - This paper deals with the results of experimental determination of load-bearing capacity of structural timber connections realized by nail metal connector plates, in the function of nail to steel plate connection rigidity. In the first group of test samples, the nails are embedded in pre-drilled holes in the steel plate. In the second group, the nails are embedded in pre-drilled holes and then the head of nail is welded to steel plate by its circumference. The main originality of the study is reflected in the achievement of rigidity of the connection of nails and the sleet plate, that is, in provision of rotation resistance, which leads to the plastic hinge formation at the surface of the steel plate, and thus to the increase of connection ductility. The study showed to what extent the degree of nail-to-plate connection rigidity affects the load-bearing capacity of structural timber member connections. Experimental testing was conducted in accordance with the provisions of Eurocode 5.
PB  - Statny Drevarsky Vyskumny Ustav
T2  - Wood Research
T1  - Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity
VL  - 63
IS  - 1
SP  - 85
EP  - 95
ER  - 
@article{
author = "Tekić, Žikica and Nenadović, Aleksandra and Đorđević, Saša M. and Lukić, Snježan",
year = "2018",
url = "http://raf.arh.bg.ac.rs/handle/123456789/309",
abstract = "This paper deals with the results of experimental determination of load-bearing capacity of structural timber connections realized by nail metal connector plates, in the function of nail to steel plate connection rigidity. In the first group of test samples, the nails are embedded in pre-drilled holes in the steel plate. In the second group, the nails are embedded in pre-drilled holes and then the head of nail is welded to steel plate by its circumference. The main originality of the study is reflected in the achievement of rigidity of the connection of nails and the sleet plate, that is, in provision of rotation resistance, which leads to the plastic hinge formation at the surface of the steel plate, and thus to the increase of connection ductility. The study showed to what extent the degree of nail-to-plate connection rigidity affects the load-bearing capacity of structural timber member connections. Experimental testing was conducted in accordance with the provisions of Eurocode 5.",
publisher = "Statny Drevarsky Vyskumny Ustav",
journal = "Wood Research",
title = "Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity",
volume = "63",
number = "1",
pages = "85-95"
}
Tekić Ž, Nenadović A, Đorđević SM, Lukić S. Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity. Wood Research. 2018;63(1):85-95
Tekić, Ž., Nenadović, A., Đorđević, S. M.,& Lukić, S. (2018). Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity.
Wood ResearchStatny Drevarsky Vyskumny Ustav., 63(1), 85-95.
Tekić Žikica, Nenadović Aleksandra, Đorđević Saša M., Lukić Snježan, "Nail metal connector plate - load-bearing capacity of connector in function of nail-to-plate connection rigidity" 63, no. 1 (2018):85-95

DSpace software copyright © 2002-2015  DuraSpace
O RAF-u | Pošaljite zapažanja

OpenAIRERCUB
 

 

Kompletan repozitorijumInstitucijeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O RAF-u | Pošaljite zapažanja

OpenAIRERCUB