In order to compare drivers' subjective impressions when exposed to high-pressure sodium versus LED street lighting, an experiment was conducted on a Belgrade street. All general requirements for an adequate comparison of subjective impressions, equal luminances being the most important, were fulfilled. A survey was conducted using a questionnaire, which the respondents filled out immediately after driving through both zones of the illuminated street. The respondents, who were young drivers (students), aged 20-25 years, were asked to select the more appropriate of the two installations regarding seven lighting parameters as well as giving their overall impression. The two regimes for which the survey was done gave opposite results. In the normal regime, where both installations had the same photopic luminance, the LED installation was evaluated as a better solution by a majority of the respondents for most of the analysed parameters. In the mesopic regime, where both installations had ...the same mesopic luminance, most of the respondents judged that the high-pressure sodium installation was the better choice.
Izvor:
Lighting Research and Technology, 2018, 50, 8, 1212-1224Izdavač:
- SAGE Publications Ltd
Finansiranje / projekti:
- Preporuke za izvođenje i pravilno korišćenje niskonaponskih električnih i gromobranskih zaštitnih instalacija i razvoj metodologije za verifikaciju njihovog kvaliteta sa aspekta zaštite građevinskih objekata od požara (RS-MESTD-Technological Development (TD or TR)-36018)
DOI: 10.1177/1477153517727802
ISSN: 1477-1535
WoS: 000452509300007
Scopus: 2-s2.0-85042554321
Institucija/grupa
Arhitektonski fakultetTY - JOUR AU - Đokić, Lidija AU - Čabarkapa, Aleksandra AU - Đuretić, Andrej PY - 2018 UR - https://raf.arh.bg.ac.rs/handle/123456789/321 AB - In order to compare drivers' subjective impressions when exposed to high-pressure sodium versus LED street lighting, an experiment was conducted on a Belgrade street. All general requirements for an adequate comparison of subjective impressions, equal luminances being the most important, were fulfilled. A survey was conducted using a questionnaire, which the respondents filled out immediately after driving through both zones of the illuminated street. The respondents, who were young drivers (students), aged 20-25 years, were asked to select the more appropriate of the two installations regarding seven lighting parameters as well as giving their overall impression. The two regimes for which the survey was done gave opposite results. In the normal regime, where both installations had the same photopic luminance, the LED installation was evaluated as a better solution by a majority of the respondents for most of the analysed parameters. In the mesopic regime, where both installations had the same mesopic luminance, most of the respondents judged that the high-pressure sodium installation was the better choice. PB - SAGE Publications Ltd T2 - Lighting Research and Technology T1 - Drivers' impressions under high-pressure sodium and LED street lighting VL - 50 IS - 8 SP - 1212 EP - 1224 DO - 10.1177/1477153517727802 ER -
@article{ author = "Đokić, Lidija and Čabarkapa, Aleksandra and Đuretić, Andrej", year = "2018", abstract = "In order to compare drivers' subjective impressions when exposed to high-pressure sodium versus LED street lighting, an experiment was conducted on a Belgrade street. All general requirements for an adequate comparison of subjective impressions, equal luminances being the most important, were fulfilled. A survey was conducted using a questionnaire, which the respondents filled out immediately after driving through both zones of the illuminated street. The respondents, who were young drivers (students), aged 20-25 years, were asked to select the more appropriate of the two installations regarding seven lighting parameters as well as giving their overall impression. The two regimes for which the survey was done gave opposite results. In the normal regime, where both installations had the same photopic luminance, the LED installation was evaluated as a better solution by a majority of the respondents for most of the analysed parameters. In the mesopic regime, where both installations had the same mesopic luminance, most of the respondents judged that the high-pressure sodium installation was the better choice.", publisher = "SAGE Publications Ltd", journal = "Lighting Research and Technology", title = "Drivers' impressions under high-pressure sodium and LED street lighting", volume = "50", number = "8", pages = "1212-1224", doi = "10.1177/1477153517727802" }
Đokić, L., Čabarkapa, A.,& Đuretić, A.. (2018). Drivers' impressions under high-pressure sodium and LED street lighting. in Lighting Research and Technology SAGE Publications Ltd., 50(8), 1212-1224. https://doi.org/10.1177/1477153517727802
Đokić L, Čabarkapa A, Đuretić A. Drivers' impressions under high-pressure sodium and LED street lighting. in Lighting Research and Technology. 2018;50(8):1212-1224. doi:10.1177/1477153517727802 .
Đokić, Lidija, Čabarkapa, Aleksandra, Đuretić, Andrej, "Drivers' impressions under high-pressure sodium and LED street lighting" in Lighting Research and Technology, 50, no. 8 (2018):1212-1224, https://doi.org/10.1177/1477153517727802 . .